Flow Pro PDF Print E-mail

Check the Revision History tab to see if you need to download the latest version.

Latest Version

 

This program will work only if you have already installed Flow Pro from your CD.

After download finishes, extract the files from the downloaded .zip file, and run Setup.exe to install the new version.

 

Download Latest Version Flow Pro

 

 

 

Revision History

Flow Pro for Windows - Revision History

-----------------------------------------------------------------------------
Ver. 2.02  March 25, 2017
  Changed help file to .chm format.
-----------------------------------------------------------------------------
Ver. 2.01  February 13, 2016
  Fixed bug that incorrectly read and wrote DOS Flow Pro .FP files. This
  affected the import and export of those files.
-----------------------------------------------------------------------------
Ver. 2.00  Novemer 1, 2015
 1. Added support for Flow Pro ver. 6 hardware.  2. New installation program implmented.
-----------------------------------------------------------------------------
Ver. 1.72a  March 1, 2015
 1. Minor change needed to accommodate new pressure sensors.
-----------------------------------------------------------------------------
Ver. 1.72  Ocotber 27, 2013
 1. Fixed bug in reading of Swirl Meter on Saenz D benches.
-----------------------------------------------------------------------------
Ver. 1.71b  January 8, 2013
 1. Fixed typo bug in labels in Test Setup.
-----------------------------------------------------------------------------
Ver. 1.71a  December 27, 2012
 1. Fixed bug in carburetor reports.
-----------------------------------------------------------------------------
Ver. 1.71  December 3, 2012
 1. Fixed bug in saving of settings for report legends.
-----------------------------------------------------------------------------
Ver. 1.70b  July 30, 2012
 1. Fixed bugs in flow calculation for range 2 of Saenz J benches.
-----------------------------------------------------------------------------
Ver. 1.69  May 26, 2010
 1. Add special features for special customer.
-----------------------------------------------------------------------------
Ver. 1.68  January 4, 2010
 1. Add support for Saenz model K bench.
-----------------------------------------------------------------------------
Ver. 1.67  August 11, 2009
 1. Made it possible to change the size of the "Open Test" window.
-----------------------------------------------------------------------------
Ver. 1.66  November 18, 2008
 1. Modified program to allow Audie Technology Depression
 Control to be used with Superflow Flow Com and SF1020 bench.
-----------------------------------------------------------------------------
Ver. 1.65  September 8, 2008
 1. Fixed bug that could cause a crash when writing some files,
  including DOS versions of Flow Pro data files..
-----------------------------------------------------------------------------
Ver. 1.64  May 30, 2008
 1. Fixed bug that failed to get pitot sensor data from Saenz digital benches.
-----------------------------------------------------------------------------
Ver. 1.63  February 20, 2008
 1. Fixed bug that prevented printing the Intake /Exhaust report.
-----------------------------------------------------------------------------
Ver. 1.62  January 4, 2008
 1. Added Intake /Exhaust report.
-----------------------------------------------------------------------------
Ver. 1.61  November 19, 2007
 1. Added support for Saenz D benches.
 2. Fixed bug in printout for Port Maps.
-----------------------------------------------------------------------------
Ver. 1.60  October 3, 2007
 1. Added provision for changing column widths in the legend at the top of
    reports.  The entries for this are in Report Setup.
-----------------------------------------------------------------------------
Ver. 1.59  July 30, 2007
 1. Added l/s as an option for air flow units in Full Metric mode.
 2. Added display of real-time flow percentage to the real-time screen.
 3. Adjusted auto-zero for version 5 hardware.
-----------------------------------------------------------------------------
Ver. 1.58  May 23, 2007
 1. Fixed bug in reading of temperature probes using Flow Pro ver. 5 hardware.
-----------------------------------------------------------------------------
Ver. 1.57  May 11, 2007
 1. Add support for FD375FP bench.
-----------------------------------------------------------------------------
Ver. 1.55  April 19, 2007
 1. Updates to authorization key support due to Windows Vista.
-----------------------------------------------------------------------------
Ver. 1.54  February 28, 2007
 1. Improvements for the Saenz J bench.
-----------------------------------------------------------------------------
Ver. 1.53  February 9, 2007
 1. Minor changes to prepare for the release of Flow Pro Expander hardware.
-----------------------------------------------------------------------------
Ver. 1.52  December 18, 2006
 1. Fixed bug that affected use of the Depression Control with Flow Quik.
-----------------------------------------------------------------------------
Ver. 1.51  October 25, 2006
 1. Fixed bug that affected exhaust calibration for Flow Data benches when
    software is in Half Metric or Full Metric mode.
-----------------------------------------------------------------------------
Ver. 1.50  August 8, 2006
 1. Fixed bug that affected only FMA benches.
-----------------------------------------------------------------------------
Ver. 1.49  August 1, 2006
 1. Added "Max Air Velocity" and "Min Air Velocity" to the list of possible
    columns in the Tests list.  These are especially useful with port maps.
-----------------------------------------------------------------------------
Ver. 1.48  June 18, 2006
 1. Added support for early versions of Superflow's Flow Com.
-----------------------------------------------------------------------------
Ver. 1.47  May 22, 2006
 1. Added saving of graphs to a bmp file.
 2. Fixed bug in graph printouts that caused 2nd legend on a new page to
    overwrite first one.
-----------------------------------------------------------------------------
Ver. 1.46  May 10, 2006
 1. Updated authorization key dll to support 64 bit computers.
 2. Made changes to handle SF1020 benches that are calibrated backwards.
 3. Added support for COM ports up to COM 9.
-----------------------------------------------------------------------------
Ver. 1.45  March 14, 2006
 1. Fixed MS bug that displayed data in the lists at the wrong location, but
    only on a only few XP machines.  Very strange!
-----------------------------------------------------------------------------
Ver. 1.44  January 14, 2006
 1. Fixed printing bug that affected Windows versions other than XP.  Thank
    you Microsoft for such wonderful inconsistency!
-----------------------------------------------------------------------------
Ver. 1.43  November 10, 2005
 1. Added real-time screen printout.
-----------------------------------------------------------------------------
Ver. 1.42  July 28, 2005
 1. Extended sensor auto-zero to depression sensor.
 2. Fixed bug in flow calculations for FMA bench.
-----------------------------------------------------------------------------
Ver. 1.41  June 4, 2005
 1. Add support for multiple range DS-300 benches.
-----------------------------------------------------------------------------
Ver. 1.40  May 1, 2005
 1. Add support for FMA brand bench.
-----------------------------------------------------------------------------
Ver. 1.39  May 2, 2005
 1. Fixed cosmetic problems that appear when running under Windows XP.
 2. Fixed problems with installation of authorization key drivers .
-----------------------------------------------------------------------------
Ver. 1.38  March 29, 2005
 1. Fixed bug that could cause error messages when importing DOS Flow Pro
    files from folders with more than 400 *.FP files.
 2. Added confirmation request when deleting tests via the right click popup
    menu.
-----------------------------------------------------------------------------
Ver. 1.37  November 21, 2004
 1. Fixed bug.  Flow Adjustment was not working for Flow Quik benches.
-----------------------------------------------------------------------------
Ver. 1.36  November 4, 2004
 1. Improved the "Copy Setup to Master List" and "Copy Head to Master List"
    operation in the Edit Test Details window.
 2. Added a "Copy Head from Master List" operation to the Edit Test Details
    window.
 3. Fixed bug that prevented reception of Swirl and Flow Quik data at the
    same time.
-----------------------------------------------------------------------------
Ver. 1.35  October 19, 2004
 1. Increased maximum number of ranges for ideal orifice bench from 6 to 9.
-----------------------------------------------------------------------------
Ver. 1.34  September 15, 2004
 1. Fixed bug in CFM calculations for DS-300 benches.
-----------------------------------------------------------------------------
Ver. 1.33  August 23, 2004
 1. Add option to include test notes on all reports.
-----------------------------------------------------------------------------
Ver. 1.32  July 29, 2004
 1. Special trick that records pressure on the pitot sensor as VELOVITY 1
    when Pitot Readings per Lift is set to -1.
 2. Loosen requirement for a stable depresssion in Auto tests from +/- 0.3 to
    +/- 0.5 inches H2O.
-----------------------------------------------------------------------------
Ver. 1.31  June 17, 2004
 1. Status message in toolbar on real-time screen now shows "MEASURING" when
    data is being gathered, even in non-auto test modes.
-----------------------------------------------------------------------------
Ver. 1.30  May 28, 2004
 1. Misc. bug fixes.
-----------------------------------------------------------------------------
Ver. 1.29     April 7, 2004
 1. Curve Names that include "CFM" now change to "CMM" in Full Metric Mode.
-----------------------------------------------------------------------------
Ver. 1.28     April 5, 2004
 1. Fixed bug that failed to record flow when using Flow Quik hardware.
-----------------------------------------------------------------------------
Ver. 1.27     March 19, 2004
 1. Fixed bug that showed blank for Mano & Range on some reports
-----------------------------------------------------------------------------
Ver. 1.25     November 3, 2003
 1. Fixed bugs introduced in ver. 1.24
-----------------------------------------------------------------------------
Ver. 1.24     August 26, 2003
 1. Added support for Mondello WFB-2800 bench.
-----------------------------------------------------------------------------
Ver. 1.23     June 5, 2003
 1. Added filter to ignore spikes in swirl and tumble.
-----------------------------------------------------------------------------
Ver. 1.21     January 31, 2003
 1. Added support for tumble meter.
 2. Made special Superflow version.
 3. Changed "Edit Details" icon on the toolbar.
 4. Updated help files.
 5. Added options for Manual Data Recording method.
-----------------------------------------------------------------------------
Ver. 1.19     November 19, 2002
 1. Fixed bug that caused problems when using the depression control with
    Flow Pro ver. 2 hardware.
-----------------------------------------------------------------------------
Ver. 1.18     September 19, 2002
 1. Fixed bug that gave error message when importing FP ver. 2 files with
    "Load after Converting" checked.
-----------------------------------------------------------------------------
Ver. 1.17     September 17, 2002
 1. Allow flow graph scales to exceed 999.9 CFM.
-----------------------------------------------------------------------------
Ver. 1.16     September 10, 2002
 1. Fixed bug that caused Swirl meter to stop working after first test is
    completed.
-----------------------------------------------------------------------------
Ver. 1.15     July 16, 2002
 1. Fix problems with Superflow's Flow Com.  Added entry for selecting bench
    model when using Flow Com.
-----------------------------------------------------------------------------
Ver. 1.14     May 3, 2002
 1. Fix problems communicating with Superflow's Flow Com on 110 and 120
    benches.
-----------------------------------------------------------------------------
Ver. 1.13     March 30, 2002
 1. Fix problems communicating with Superflow's Flow Com.
-----------------------------------------------------------------------------
Ver. 1.12     March 19, 2002
 1. Fix problems with install of update.
-----------------------------------------------------------------------------
Ver. 1.11     March 7, 2002
 1. Fixed problems with entry of keyboard entered CFM tests.
 2. Fixed bug that caused crash when clicking spinner if line step size = 0.
-----------------------------------------------------------------------------
Ver. 1.10    February 27, 2002
 1. Several changes that affect communicating with Superflow's Flow Com.
-----------------------------------------------------------------------------
Ver. 1.09    February 25, 2002
 1. Fixed problem communicating with Flow Pro ver. 2 hardware.
 2. Changed confusing messages that appear when data is copied back to the
    master test setup list.
 3. On keyboard entered carburetor tests venturi can be now entered as a
    number (0 to 4) or as "LF", "RF", "ALL", etc.
 4. Added support for version FP4-AR hardware.
-----------------------------------------------------------------------------
Ver. 1.08    January 18, 2002
 1. Fixed problem with calculation of coefficents and Std Flow when the
    standard flow method is "Orifice" and the number of valves is greater
    than 1 per port.
 2. Fixed problems with printing of carburetor graphs and reports.
-----------------------------------------------------------------------------
Ver. 1.07    January 2, 2002
 1. Fixed problem with calculation of A Velocity values.
 2. Added ability to use Enter key to perform the same job as the foot switch
    in the real-time screen.
 3. Added option to hide the lists in the carburetor and head graph screens.
    This lets the graph fill almost the whole screen.
-----------------------------------------------------------------------------
Ver. 1.06    December 28, 2001
 1. Fixed problems with legend at bottom of graph printouts.
-----------------------------------------------------------------------------
Ver. 1.05    December 8, 2001
 1. Fixed problem with word wrap in Test Notes.
 2. Added missing dependancy files to Setup.
-----------------------------------------------------------------------------
Ver. 1.04    December 4, 2001
 1. Fixed problem on "Compare Tests" reports that have Total or Variance
    columns.
 2. Added command to the file menu a command to change the database file.
-----------------------------------------------------------------------------
Ver. 1.03    November 23, 2001
 1. Fixed bug that did not copy all of a head's data when starting a new test
    or copying a head setup.
-----------------------------------------------------------------------------
Ver. 1.02    November 8, 2001
 1. Fixed bug that caused errors in sensor calibration when changing between
    metric and English modes.
 2. Fixed bug that could cause errors when saving files depending upon your
    Windows' settings for formatting time.
 3. Fixed bug in calculation of Ax Coefficients.
 4. Refined support for Superflow 1020 and Flow Com.
-----------------------------------------------------------------------------
Ver. 1.01    September 28, 2001
 1. Fixed bug that caused temperature on real-time screen to disappear when
    it was over 100 degrees.
-----------------------------------------------------------------------------
Ver. 1.00    September 4, 2001
 1. Fixed bug that crashed program when attempting to import DOS files when
    there are no customers in the customer list.
 2. Supressed range change advice in real-time screen when bench is single
    range.
-----------------------------------------------------------------------------
Ver. 3.06 Beta   August 22, 2001
 1. Added "Make test the reference" to popup menus.
 2. Fix bug when deleting or closing map tests via popup menu.
 3. Limited length of several entries to database field size.
 4. Fix storing of multi-line notes.
 5. Fixed problems with carburetor tests on the real-time screen.
-----------------------------------------------------------------------------
Ver. 3.05 Beta   August 17, 2001
 1. Fixed bug that sometimes caused error messages when re-entering the
    real-time test screen.
 2. Disabled access to entry blanks when picked destination for "Copy to
    Master Setup" and "Copy to Master Head" lists.
 3. Fixed problems with carburetor tests on the real-time screen.
 4. Added popup menu when tests list is right clicked.
 5. Added auto-increment of Test Name.
 6. Update manual & help screens.
-----------------------------------------------------------------------------
Ver. 3.01 Beta   August 3, 2001
 1. Fixed bug in ver. 3.00 that caused communication problems with some
    versions of Flow Pro hardware.
 2. Fixed bug:  Graph would not print if Comments on Printout was active.
-----------------------------------------------------------------------------
Ver. 3.00 Beta   July 26, 2001
 1. Added Import & Export of Tests and Test Setups to Windows version files.
-----------------------------------------------------------------------------
Ver. 2.07 Beta   June 24, 2001
 1. Add support for Holley jets.
-----------------------------------------------------------------------------
Ver. 2.06 Beta   June 15, 2001
 1. Fix problems with "Comments on Printouts".
 2. Enable the print icon and menu items for carburetor graph.
-----------------------------------------------------------------------------
Ver. 2.05 Beta   June 11, 2001
 1. First version update available via website.
 2. Added selecting customer when importing FP DOS files.
 3. Added option to copy a test's setup or head to the master Test Setup list.
 4. Fixed various bugs.

 